Input DC (PV side) | |||
Recommended max. PV array size | 60 kW | 80 kW | 100 kW |
Max. usable PV input power | 60 kW | 80 kW | 96 kW |
Max. input voltage | 1000 V | ||
Rated voltage | 600V | ||
Start-up voltage | 180 V | ||
MPPT voltage range | 150 - 850 V | ||
Max. input current | 40A / 40A / 40A | 4 × 40A | |
Max. short circuit current | 60A / 60A / 60A | 4 × 60A | |
MPPT number/Max. input strings number | 3 / 6 | 4 / 8 | |
Battery | |||
Battery type | Li-ion | ||
Battery voltage range | 150 - 800 V | ||
Max. charge /discharge power | 33 kW | 44 kW | 55 kW |
Max. charge / discharge current | 70 A × 2 | ||
No. of battery inputs | 2 | ||
Max. charge / discharge power of each input | 33 kW | 35 kW | 35 kW |
Communication | CAN/RS485 | ||
Output AC (Grid side) | |||
Rated output power | 30 kW | 40 kW | 50 kW |
Max. apparent output power | 30 kVA | 40 kVA | 50 kVA |
Rated grid voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||
Rated grid frequency | 50 Hz / 60 Hz | ||
Rated grid output current | 45.6A / 43.3A | 60.8A / 57.7A | 76A / 72.2A |
Max. output current | 45.6A / 43.3A | 60.8A / 57.7A | 76A / 72.2A |
Power factor | > 0.99 (0.8 leading - 0.8 lagging) | ||
THDi | < 3% | ||
Input AC (Grid side) | |||
Max. AC passthrough current | 91.2A / 86.6A | 121.6A / 115.4A | 152A / 144.4A |
Rated input voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||
Rated input frequency | 50 Hz/60 Hz | ||
Input Generator | |||
Max. input power | 30 kW | 40 kW | 50 kW |
Rated input current | 45.6A / 43.3A | 60.8A / 57.7A | 76A / 72.2A |
Rated input voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||
Rated input frequency | 50 Hz / 60 Hz | ||
Output AC (Back-up) | |||
Rated output power | 30 kW | 40 kW | 50 kW |
Max. apparent output power | 1.6 times of rated power, 2 s | ||
Back-up switch time | < 10ms | ||
Rated output voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||
Rated frequency | 50 Hz / 60 Hz | ||
Rated output current | 45.6A / 43.3A | 60.8A / 57.7A | 76A / 72.2A |
THDv (@linear load) | <2% | ||
Efficiency | |||
Max. efficiency | 97.8% | ||
EU efficiency | 97.4% | ||
BAT charged by PV Max. efficiency | 98.5% | ||
BAT charged/discharged to Ac Max. efficiency | 97.5% | ||
General Data | |||
Dimensions (W*H*D) | 530 × 880 × 290 mm | ||
Weight | 73 kg | ||
Topology | Transformerless | ||
Self-consumption (night) | < 35w | ||
Operating ambient temperature range | -25~+60°C | ||
Relative humidity | 0-95% | ||
Ingress protection | IP66 | ||
Cooling concept | Intelligent redundant fan-cooling | ||
Max. operation altitude | 4000 m | ||
Grid connection standard | G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1/EN 50549-10, VDE 0126/UTE C 15/VFR:2019, NTS 631/RD 1699/RD 244/UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA,PORTARIA Nº 140,DE 21 DE MARÇO DE 2022 | ||
Safety/EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011 | ||
Features | |||
PV connection | MC4 Quick connection plug | ||
Battery connection | Terminal connector | ||
AC connection | Terminal Block | ||
Display | 7.0" LCD display & Bluetooth + APP | ||
Communication | CAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN |
Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Inverter
Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Inverter
AI intelligently manages charging and discharging based on TOU
Adapt to third party VPP platform, frequency service provider
Supports 100% three-phase unbalanced output
200% PV input capacity to maximize solar energy utilization
Max. 160% overload capability in off-grid mode
Charging and discharging currents up to 140A
Switching time < 10ms
-
Q :
1. How many piececs MPPT inside?
A :
With 4 MPPTs and a 40A/MPPT input current capacity, they maximize the advantages of rooftop PV power.
-
Q :
2. How much does this inverter support three-phase unbalanced output?
A :
Supports 100% three-phase unbalanced output
-
Q :
3. What's the overload capability in off-grid mode?
A :
Max. 160% overload capability in off-grid mode
-
Q :
4. What kind of battery types are supported?
A :
Compatible with high voltage 120-600V lithium
-
Q :
5. What's the switching time?
A :
Switching time< 10ms
-
Q :
6. Is remote monitoring available?
A :
Yes, it supports Wi-Fi and optional 4G connectivity for real-time cloud or app-based monitoring
Related Products
-
Solis-(215-255)K-EHV-5G 215KW 255KW Three Phase Grid-Tied Inverter
Learn More -
Solis S6-GC(80-125)K 100KW 110KW 125KW Three Phase Grid-Tied Inverter
Learn More -
Solis S6-EH3P(3-10)K-H-EU 5KW 6KW 8KW 10KW Three Phase High Voltage Energy Storage Inverter
Learn More -
Solis S6-GC3P(150-200)K07-ND 150KW 200KW On Grid Inverter For C&I Solutions
Learn More