Solis 12kW 14kW 16kW Single Phase Low Voltage Energy Storage Inverter

  • Solis S6-EH1P(12-16)K03-NV-YD-L 14KW 16KW Home Use Single Phase Low Voltage Energy Storage Inverter for Commercial Sale
  • Solis Hot Model S6-EH1P(12-16)K03-NV-YD-L 12KW 14KW Single Phase Low Voltage Energy Storage Inverter with High Quality
  • Solis Hot Model S6-EH1P(12-16)K03-NV-YD-L 16KW Single Phase Low Voltage Energy Home Storage Inverter
  • Solis S6-EH1P(12-16)K03-NV-YD-L 12KW 14KW 16KW Single Phase Low Voltage Energy Storage Inverter to Parallel
  • Solis S6-EH1P(12-16)K03-NV-YD-L 14KW 16KW Home Use Single Phase Low Voltage Energy Storage Inverter for Commercial Sale
  • Solis Hot Model S6-EH1P(12-16)K03-NV-YD-L 12KW 14KW Single Phase Low Voltage Energy Storage Inverter with High Quality
  • Solis Hot Model S6-EH1P(12-16)K03-NV-YD-L 16KW Single Phase Low Voltage Energy Home Storage Inverter
  • Solis S6-EH1P(12-16)K03-NV-YD-L 12KW 14KW 16KW Single Phase Low Voltage Energy Storage Inverter to Parallel

Solis 12kW 14kW 16kW Single Phase Low Voltage Energy Storage Inverter

    10 seconds of 200% overload capability
    Multiple inverters can operate together to form a microgrid
    Generator-compatible to extend backup duration during grid power outage
    Supports dual backup ports for intelligent control of critical and non-critical loads
    Automatic switchover time is <4ms, providing seamless transitions from grid to backup
    Supports a maximum input current of 20A, making it ideal for all high-power PV modules of any brand

Share:

Models12K14K16K
Input DC (PV side)
Recommended max. PV array size24 kW28 kW32 kW
Max. usable PV input power19.2 kW22.4 kW22.4 kW
Max. input voltage550 V
Rated voltage380 V
Start-up voltage100 V
MPPT voltage range80-520 V
Max. input current40 A / 40 A / 40 A
Max. short circuit current50 A / 50 A / 50 A
MPPT number/Max. input strings number3/6
Battery
Battery typeLi-ion / Lead-acid
Battery voltage range40 - 60 V
Max. charge / discharge power12 kW14 kW16 kW
CommunicationCAN/RS485
Output AC (Grid side)
Rated output power12 kW14 kW16 kW
Operation phaseL/N/PE
Rated grid voltage220 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current54.5 A / 52.2 A63.6 A / 60.9 A72.7 A / 69.6 A
Power factor>0.99 (0.8 leading - 0.8 lagging)
THDi<3%
Input AC (Grid side)
Input voltage range187-253 V
Max. input current81.8 A / 78.3 A95.5 A / 91.3 A109.1 A / 104.3 A
Frequency range45-55 Hz/55-65 Hz
Output AC (Back-up)
Rated output power12 kW14 kW16 kW
Max. apparent output power2 times of rated power, 10 s
Back-up switch time<4 ms
Rated output voltageL/N/PE, 220 V / 230 V
Rated frequency50 Hz / 60 Hz
Rated output current54.5 A / 52.2 A63.6 A / 60.9 A72.7 A / 69.6 A
THDv (@linear load)<3%
Input Generator
Max. input power12 kW14 kW16 kW
Max. input current54.5 A / 52.2 A63.6 A / 60.9 A72.7 A / 69.6 A
Rated input frequency50 Hz / 60 Hz
Efficiency
Max. efficiency97.6%
EU efficiency97.2%
BAT charged by PV Max. efficiency> 94.9%
BAT charged/discharged to AC Max. efficiency> 94.33%/93.51%
Protection
Surge protectionYes
DC reverse-polarity protectionYes (PV only)
Ground fault monitoringYes
Integrated AFCI 2.0Optional
Protection class/Over voltage categoryI / II (PV and BAT), III (MAINS and BACKUP and GEN)
General Data
Dimensions (W*H*D)464*763*282 mm
Weight48.5 kg
TopologyTransformerless
Operating ambient temperature range-25 ~ +60°C
Ingress protectionIP66
Cooling conceptIntelligent redundant fan-cooling
Max. operation altitude4000 m
Grid connection standardNRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530
Safety/EMC standardIEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
DC connectionMC4 plug (PV port) / Terminal Block (BAT port)
AC connectionTerminal Block
DisplayLCD  + APP
CommunicationRS485, Optional: Cellular, Wi-Fi, LAN

Q :

1. What'S the overload capability

A :

10 seconds of 200% overload capability

Q :

2. What's the maximum charge/discharge current?

A :

The battery's DC side can handle a maximum charge/discharge current of up to 290A, allowing it to store more surplus energy generated by PV systems

Q :

3. What's the automatic switchover time

A :

Automatic switchover time is <4ms, providing seamless transitions from grid to backup

Q :

4. What kind of battery types are supported?

A :

Compatible with low voltage 48-60V lithium

Q :

5. What are the dual AC outputs used for?

A :

One output is for essential loads (backup), the other for non-critical loads, allowing smart energy prioritization.

Q :

6. Is remote monitoring available?

A :

Yes, it supports Wi-Fi and optional 4G connectivity for real-time cloud or app-based monitoring.