Models | 75K | 80K | 100K | 125K |
Input DC (PV side) | ||||
Recommended max. PV array size | 150 kW | 160 kW | 200 kW | 240 kW |
Max. usable PV input power | 150 kW | 160 kW | 200 kW | 240 kW |
Max. input voltage | 1000 V | |||
Rated voltage | 600 V | |||
Start-up voltage | 180 V | |||
MPPT voltage range | 150 - 950 V | |||
Max. input current | 10 × 42 A | |||
Max. short circuit current | 10 × 60 A | |||
MPPT number / Max. input strings number | 10 / 20 | |||
Battery | ||||
Battery type | Li-ion | |||
Battery voltage range | 300 - 950 V | |||
Max.charge / discharge current | 200 A / 100 A + 100 A | |||
Number of battery ports | 2 | |||
Max. charge / discharge current of each port | 100 A | |||
Communication | CAN / RS485 | |||
Output AC (Grid side) | ||||
Rated output power | 75 kW | 80 kW | 100 kW | 125 kW |
Max. apparent output power | 75 kVA | 80 kVA | 100 kVA | 125 kVA |
Rated grid voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | |||
Rated grid frequency | 50 Hz / 60 Hz | |||
Rated grid output current | 114 A / 108.3 A | 121.6 A / 115.5 A | 152 A / 144.3 A | 180.4 A / 189.9 A |
Power factor | > 0.99 (0.8 leading - 0.8 lagging) | |||
THDi | < 3% | |||
Input AC (Grid side) | ||||
Max. input current | 250 A | |||
Output AC (Back-up) | ||||
Rated output power | 75 kW | 80 kW | 100 kW | 125 kW |
Max. apparent output power | 1.2 times of rated power, 10 mins; 1.4 times of rated power, 100 s;1.6 times of rated power, 10 s; 2 times of rated power, 200 ms | |||
Back-up switch time | < 10 ms | |||
Rated output voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | |||
Rated frequency | 50 Hz / 60 Hz | |||
THDv (@linear load) | < 2% | |||
Efficiency | ||||
Max. efficiency | 97.6% | |||
EU efficiency | 97.2% | |||
BAT charged / discharged to AC max. efficiency | 97.0% | |||
Protection | ||||
Anti-islanding protection | Yes | |||
Output over current protection | Yes | |||
Short circuit protection | Yes | |||
Integrated DC switch | Yes | |||
DC reverse-polarity protection | Yes | |||
Surge protection | DC Type II / AC Type II | |||
Integrated AFCI 2.0 | Yes | Optional | Optional (Brazil: Yes) | |
Protection class / Over voltage category | I / II | |||
General Data | ||||
Max. allowable phase imbalance (grid & back-up) | 100% | |||
Max. power per phase (grid & back-up) | 25.00 kW | 26.66 kW | 33.33 kW | 41.66 kW |
Dimensions (W × H × D) | 1174 × 814 × 400 mm | |||
Weight | 170 kg | |||
Topology | Transformerless | |||
Operating ambient temperature range | -25 ~ +60°C | |||
Ingress protection | IP66 | |||
Cooling concept | Intelligent fan-cooling | |||
Max. operation altitude | 3000 m | |||
Grid connection standard | 75K: ORDINANCE (PORTARIA) NO.140, ORDINANCE NO. 515; 100K/125K: NBR 16149, NBR 16150, IEC 62116;80K/100K/125K: G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1&2/EN 50549-10, VDE 0126/UTE C 15/VFR:2019, NTS 631/RD 1699/ RD 244/UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683,EN 50530, MEA, PEA,PORTARIA Nº 140, DE 21 DE MARÇO DE 2022 | |||
Safety / EMC standard | 75K/80K/100K/125K: IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011; 100K/125K: IEC 61000-3-4/-5/-11/-12 | |||
Features | ||||
PV connection | MC4 Quick connection plug | |||
Battery connection | Terminal connector | |||
AC connection | Terminal block | |||
Display | 7.0" LCD display & Bluetooth + APP | |||
Communication | CAN, RS485-115200, Ethernet, Optional: Wi-Fi, Cellular, LAN |
Solis S6-EH3P(75-125)K10-NV-YD-H 75KW 80KW 100KW 125KWThree Phase High Voltage Energy Storage Inverter
Solis S6-EH3P(75-125)K10-NV-YD-H 75KW 80KW 100KW 125KWThree Phase High Voltage Energy Storage Inverter
Adapt to third party VPP platform, frequency service provider
Compatible with mainstream lithium batteries
Support Solis C&I battery solution
Easily expand system capacity using parallel connections and AC coupling
Supports 100% three-phase unbalanced output
200% PV input capacity to maximize solar energy utilization
-
Q :
1. How many piececs MPPT inside?
A :
10 integrated MPPTs with a string current capacity of up to 20A
-
Q :
2. How much does this inverter support three-phase unbalanced output?
A :
Supports 100% three-phase unbalanced output
-
Q :
3. What's the pv input capacity?
A :
200% PV input capacity to maximize solar energy utilization
-
Q :
4. What's the charging and discharging currents?
A :
Charging and discharging currents of up to 200A
-
Q :
5. What's the switching time?
A :
Switching time< 10ms
-
Q :
6. Is remote monitoring available?
A :
Yes, it supports Wi-Fi and optional 4G connectivity for real-time cloud or app-based monitoring
Related Products
-
Solis S6-GC(80-125)K 100KW 110KW 125KW Three Phase Grid-Tied Inverter
Learn More -
Solis S6-GC3P(150-200)K07-ND 150KW 200KW On Grid Inverter For C&I Solutions
Learn More -
Solis S6-EH1P(12-16)K03-NV-YD-L 12KW 14KW 16KW Single Phase Low Voltage Energy Storage Inverter
Learn More -
Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Inverter
Learn More