Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Inverter

  • Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Factory Inverter for Sale
  • Solis S6-EH3P(30-50)K-H-ND Different Model 30KW 40KW 50KW Three Phase High Voltage Energy Storage Factory Inverter
  • Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Factory Storage Inverter
  • Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Inverter for Farm
  • Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Factory Inverter for Sale
  • Solis S6-EH3P(30-50)K-H-ND Different Model 30KW 40KW 50KW Three Phase High Voltage Energy Storage Factory Inverter
  • Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Factory Storage Inverter
  • Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Inverter for Farm

Solis S6-EH3P(30-50)K-H-ND 30KW 40KW 50KW Three Phase High Voltage Energy Storage Inverter

    AI intelligently manages charging and discharging based on TOU
    Adapt to third party VPP platform, frequency service provider
    Supports 100% three-phase unbalanced output
    200% PV input capacity to maximize solar energy utilization
    Max. 160% overload capability in off-grid mode
    Charging and discharging currents up to 140A
    Switching time < 10ms

Share:

Models30K40K50K
Input DC (PV side)
Recommended max. PV array size60 kW80 kW100 kW
Max. usable PV input power60 kW80 kW96 kW
Max. input voltage1000 V
Rated voltage600V
Start-up voltage180 V
MPPT voltage range150 - 850 V
Max. input current40A / 40A / 40A4 × 40A
Max. short circuit current60A / 60A / 60A4 × 60A
MPPT number/Max. input strings number3 / 64 / 8
Battery
Battery typeLi-ion
Battery voltage range150 - 800 V
Max. charge /discharge power33 kW44 kW55 kW
Max. charge / discharge current70 A × 2
No. of battery inputs2
Max. charge / discharge power of each input33 kW35 kW35 kW
CommunicationCAN/RS485
Output AC (Grid side)
Rated output power30 kW40 kW50 kW
Max. apparent output power30 kVA40 kVA50 kVA
Rated grid voltage3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current45.6A / 43.3A60.8A / 57.7A76A / 72.2A
Max. output current45.6A / 43.3A60.8A / 57.7A76A / 72.2A
Power factor> 0.99 (0.8 leading - 0.8 lagging)
THDi< 3%
Input AC (Grid side)
Max. AC passthrough current91.2A / 86.6A121.6A / 115.4A152A / 144.4A
Rated input voltage3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated input frequency50 Hz/60 Hz
Input Generator
Max. input power30 kW40 kW50 kW
Rated input current45.6A / 43.3A60.8A / 57.7A76A / 72.2A
Rated input voltage3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated input frequency50 Hz / 60 Hz
Output AC (Back-up)
Rated output power30 kW40 kW50 kW
Max. apparent output power1.6 times of rated power, 2 s
Back-up switch time< 10ms
Rated output voltage3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated frequency50 Hz / 60 Hz
Rated output current45.6A / 43.3A60.8A / 57.7A76A / 72.2A
THDv (@linear load)<2%
Efficiency
Max. efficiency97.8%
EU efficiency97.4%
BAT charged by PV Max. efficiency98.5%
BAT charged/discharged to Ac Max. efficiency97.5%
General Data
Dimensions (W*H*D)530 × 880 × 290 mm
Weight73 kg
TopologyTransformerless
Self-consumption (night)< 35w
Operating ambient temperature range-25~+60°C
Relative humidity0-95%
Ingress protectionIP66
Cooling conceptIntelligent redundant fan-cooling
Max. operation altitude4000 m
Grid connection standardG99, VDE-AR-N 4105/VDE V 0124, EN 50549-1/EN 50549-10, VDE 0126/UTE C 15/VFR:2019, NTS 631/RD 1699/RD 244/UNE 206006/UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA,PORTARIA Nº 140,DE
21 DE MARÇO DE 2022
Safety/EMC standardIEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011
Features
PV connectionMC4 Quick connection plug
Battery connectionTerminal connector
AC connectionTerminal Block
Display7.0" LCD display & Bluetooth + APP
CommunicationCAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN

Q :

1. How many piececs MPPT inside?

A :

With 4 MPPTs and a 40A/MPPT input current capacity, they maximize the advantages of rooftop PV power.

Q :

2. How much does this inverter support three-phase unbalanced output?

A :

Supports 100% three-phase unbalanced output

Q :

3. What's the overload capability in off-grid mode?

A :

Max. 160% overload capability in off-grid mode

Q :

4. What kind of battery types are supported?

A :

Compatible with high voltage 120-600V lithium

Q :

5. What's the switching time?

A :

Switching time< 10ms

Q :

6. Is remote monitoring available?

A :

Yes, it supports Wi-Fi and optional 4G connectivity for real-time cloud or app-based monitoring