Deye SUN-120/125/130/135/136K-G01P3-EU-AM8 Three Phase 120kw 125kw 130kw 135kw 136kw On Grid Solar Inverter for Commercial

  • Deye High Efficiency 3-Phase On-grid Inverter with Zero-Export and VSG for Grid Independence Supplier
  • Deye 125kW On-grid Inverter Protection & Safety Functions Factory
  • Deye 135kW 136kW On-grid Inverter Supplier for Farm
  • Deye High Efficiency 3-Phase On-grid Inverter with Zero-Export and VSG for Grid Independence Supplier
  • Deye 125kW On-grid Inverter Protection & Safety Functions Factory
  • Deye 135kW 136kW On-grid Inverter Supplier for Farm

Deye SUN-120/125/130/135/136K-G01P3-EU-AM8 Three Phase 120kw 125kw 130kw 135kw 136kw On Grid Solar Inverter for Commercial

    IP Rating: IP65 (Dustproof and Water-resistant for Outdoor Installation).
    Max. DC Input Voltage: 1100V (for All Models: SUN-120K to SUN-136K).
    MPPT Operating Range: 200V–1000V (Ensures Efficient Power Conversion Under Varying PV Conditions).
    Max. Efficiency: >98% (High Energy Conversion Performance).
    Rated AC Grid Voltage: 400V (Three-phase Output).
    Warranty: Standard 5 years (Extendable Options Available).

Partager :

Spefication

ModèleSUN-120K-G01P3-EU-AM8SUN-125K-G01P3-EU-AM8SUN-130K-G01P3-EU-AM8SUN-135K-G01P3-EU-AM8SUN-136K-G01P3-EU-AM8
Côté entrée
Puissance max. Puissance d'entrée DC (kW)180187.5195202.5204
Tension d'entrée DC (V) max. Tension d'entrée DC (V)1100
Tension d'entrée DC au démarrage (V)250
Plage de fonctionnement MPPT (V)200-1000
Courant d'entrée max. Courant d'entrée DC (A)40+40+40+40+40+40+40+40
Courant de court-circuit max. Courant de court-circuit (A)60+60+60+60+60+60+60+60
Nombre de trackers MPP8
Nombre de cordes par MPP Tracker4+4+4+4+4+4+4+4
Côté sortie
Puissance de sortie nominale (kW)120125130135136
Puissance active max. Puissance active (kW)132135135135136
Rated Output Voltage/Range (V)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)
Fréquence nominale du réseau (Hz)50 / 60 (en option)
Phase de fonctionnementTriphasé
Courant nominal de sortie du réseau AC (A)181.9/174189.4/181.2197/188.5204.6/195.7206.1/197.2
Courant de sortie max. Courant de sortie CA (A)200/191.4204.6/195.7204.6/195.7204.6/195.7206.1/197.2
Facteur de puissance de sortie>0.99
Distorsion harmonique totale du courant (THDi)<3%
Courant d'injection DC (mA)<0,5%
Gamme de fréquences de la grille45~55 or 55~65 (Optional)
Efficacité
Max. Efficacité98.8%
Efficacité de l'euro98.3%
Efficacité MPPT>99%
Protection de l'environnement
DC Reverse-Polarity ProtectionOui
AC Short Circuit ProtectionOui
AC Output Overcurrent ProtectionOui
Output Overvoltage ProtectionOui
Insulation Resistance ProtectionOui
Ground Fault MonitoringOui
Anti-islanding ProtectionOui
Temperature ProtectionOui
Integrated DC SwitchOui
Remote Software UploadOui
Remote Change of Operating ParametersOui
Surge ProtectionDC Type II / AC Type II
Données générales
Taille de l'armoire (LxHxP mm)1006×516×325.5 (Excluding Connectors and Brackets)
Poids (kg)103
TopologieSans transformateur
Internal Consumption<1W (Night)
Running Temperature-25-65℃, >45℃ Derating
Ingress ProtectionIP65
Noise Emission (Typical)≤65 dB
Cooling ConceptRefroidissement intelligent
Permissible Altitude (m)4000
Designed Lifetime>20 Years
Grid Connection StandardIEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110
Operating Surroundings Humidity0-100%
Sécurité CEM / NormeIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Caractéristiques
AffichageLCD 240 × 160
InterfaceRS485/RS232/Wifi/LAN

Physical Diagram and Connection Method

Q :

Quelles sont les protections de sécurité incluses ?

A :

Over-voltage/under-voltage, islanding protection, arc-fault detection, and insulation monitoring (Section 10).

Q :

Can multiple inverters work in parallel?

A :

Yes, configure one as "Master" and others as "Slaves" with a shared meter (Section 7.1).

Q :

What is the operating temperature range?

A :

-25°C to +60°C (derating above 40°C; avoid direct sunlight, Section 4.1).

Q :

How to troubleshoot error codes like F24 (DC insulation fault)?

A :

Check PV panel grounding and cable insulation; restart or contact support (Section 10.1).

Q :

What cable specifications are required for AC/DC connections?

A :

DC: 4–6 mm² PV cable; AC: 107 mm² (4/0AWG) for grid connection (Tables 5.1–5.2).